BAL 29 Reference Guide


what are the bal 29 building requirements

Building or renovating property in bushfire-prone areas across South Australia? Understanding your BAL-29 rating is crucial to ensure your home meets safety requirements while remaining compliant with local regulations.

At Bush Fire Hazard Assessments (BFHA), we’ve helped countless property owners and developers navigate the complexities of bushfire protection standards across the Adelaide Hills, Onkaparinga, and Mitcham regions, and beyond. This guide gives you a handy breakdown of everything you need to know about BAL-29 classifications, requirements, and practical solutions to protect your investment.

Not sure what BAL rating applies to your property? Get a free consultation.

What is BAL 29?

BAL-29 (Bushfire Attack Level 29) represents a moderate to high-risk classification within Australia’s bushfire protection standards. The number “29” specifically refers to the heat exposure threshold measured in kilowatts per square metre (kW/m²) that a building might experience during a bushfire event.

For South Australian properties, a BAL-29 rating indicates your property sits in an area where ember attack is likely and where heat exposure between 19-29 kW/m² could occur during a bushfire. This puts BAL-29 in the middle of the BAL rating spectrum, higher than BAL-12.5 and BAL-19, but lower than BAL-40 and BAL-FZ (Flame Zone).

This classification directly influences construction requirements, materials selection, and the design considerations needed to protect your property in the event of a bushfire. Understanding your specific BAL rating is the essential first step in the building or renovation process for properties in bushfire-prone areas.

Curious how this figure is actually worked out? See our guide on how to calculate your BAL rating.

Top BAL-29 Requirements for South Australian Properties

When building or renovating a property with a BAL-29 rating in South Australia, you must follow specific standards that are designed to reduce vulnerability to ember attack and radiant heat exposure. Some of the key ones are:

Subfloor Supports and Framing

For BAL-29 properties, subfloor supports for unenclosed subfloors must be constructed using:

  • Non-combustible materials (concrete, steel, aluminium mesh, etc.)
  • Bushfire-resistant timber as specified in AS3959

Also, the gap between the ground and the lowest floor sections should be enclosed with non-combustible material or bushfire-resisting timber if the bearers and joists sit less than 400mm from the ground.

External Walls and Cladding

External walls for a BAL-29 rated property must be:

  • Constructed using brick, concrete blocks, rammed earth, stone or other non-combustible materials
  • If using timber, it must meet a minimum thickness
  • Sheet materials require non-combustible cladding like fibre cement or steel sheeting
  • All joints must be sealed against ember penetration

BAL-29 Windows and Related Protection Requirements

Proper BAL-29 windows are essential for property protection. You’ll need:

  • Frames made from metal, bushfire-resistant timber, or other tested materials
  • Bushfire shutters to protect non-compliant windows
  • A minimum of 5mm toughened glass for all window assemblies
  • Openable portions fitted with seals (metal or bushfire-resistant timber) to prevent ember penetration
bal 29 meaning

BAL-29 Doors That Provide External Access

All external BAL-29 doors must provide robust protection against ember attack:

  • External side-hung doors and sliding doors must be non-combustible, or made from solid timber with a minimum thickness of 35mm
  • Tight-fitting weather strips must be utilised
  • All glass panels must be made from 5mm or thicker toughened glass
  • Add bushfire shutters or metal screens for added protection
  • Garage doors can be made from non-combustible materials, bushfire-resisting timber, or 6mm cement sheets

Roofing and Gutters

Roof systems for BAL-29 properties require:

  • Full sarking, seals to stop ember entry, and the use of non-combustible covering materials (e.g., concrete or terracotta tiles, metal sheets)
  • Gutters and downpipes should preferably be metal and/or have gutter guides installed to prevent the build-up of debris

Verandahs, Decks, and Other Outdoor Spaces

There are BAL-29 decking requirements and rules for other attached structures:

  • Only use non-combustible materials for decking or choose bushfire-resistant timber when you have unenclosed deck supports and framing
  • For enclosed subfloor spaces, these only need to match the wall requirements
  • Verandah and carport roofs should meet the same requirements as the main roof of the house, or else be separated by an external wall that conforms to BAL-29 wall requirements

Need a BAL assessment for your BAL 29 property? Get a quote from SA’s accredited experts.

what is the bal 29 fire rating

Navigating Council Approvals

Councils across South Australia may interpret requirements differently. Our expertise with local BAL assessments helps streamline this process and make it much less stressful for you.

For instance, our team recently worked with a developer on a multi-dwelling project in the Adelaide Hills with a BAL-29 rating. The project faced several challenges, one of which was that the client wanted to keep large glass areas in the building for views. We recommended multiple screening solutions compliant with BAL-29 ratings and helped our client maintain the views while still providing adequate bushfire protection.

Get Help with BAL 29 Guidelines

Building in BAL 29 areas requires careful attention to detail and a thorough understanding of construction requirements. With nearly a decade of experience across South Australia’s bushfire-prone regions, our BFHA team brings expert knowledge to every project. For personalised advice on your property or to arrange a detailed BAL assessment, contact our team for a chat or a quote. We’re here to guide you through every step of the process.