BAL 40 Reference Guide


what are the bal 40 construction requirements for homes in bush fire prone areas

Building or renovating in high-risk bushfire areas is daunting, but the more info you have, the easier it is. BAL 40 isn’t just another building code to tick off; it’s serious protection for some of South Australia’s most fire-prone spots. We’ve seen how these requirements can make or break a property when the worst happens. Here, we’re giving you the straight talk on BAL-40, with info on what it means for your build, your budget, and ultimately, your peace of mind.

Not sure what BAL rating applies to your property? Get a free consultation.

What is BAL-40?

BAL 40 (Bushfire Attack Level 40) represents a high-risk classification within our country’s bushfire protection standards. The number “40” shows the heat exposure threshold measured in kilowatts per square metre (kW/m²) a building could experience during a bushfire period.

Basically, a BAL-40 rating indicates your property is situated in an area where there’s a big risk of ember attack, burning debris ignited by windborne embers, and a likelihood of exposure to a high level of radiant heat between 29-40 kW/m² during a bushfire. Exposure to flames is likely at this level. This places BAL-40 near the top end of the BAL rating spectrum, higher than BAL-12.5, BAL-19, and BAL-29, with only BAL-FZ (Flame Zone) as a more severe classification.

This high-level classification massively impacts construction requirements, your chosen materials, and other design and building factors involved in ensuring your property is as safe as possible during intense bushfire conditions. Knowing the BAL rating of your property is a must before you start any building or renovation work on your South Australian property.

Curious how this figure is actually worked out? See our guide on how to calculate your BAL rating.

BAL-40 Requirements for South Australian Properties

Building or renovating a property with a BAL-40 rating in South Australia involves stringent construction requirements that exceed those of lower ratings. Some of the prime BAL-40 construction requirements you should know about are:

Subfloor Support Needs

For BAL-40 properties, subfloor construction demands:

  • All unenclosed subfloor supports, such as stumps, must be made from non-combustible materials only (e.g., concrete, masonry, steel) or some other type of system that conforms with the Standards
  • Also for unenclosed subfloors, the bearers and joists must be non-combustible or at least protected, on the underside, with non-combustible materials like metal or cement sheeting
  • For elevated floors with an enclosed subfloor space, there are no special requirements for any parts, provided the enclosure is completed with a wall that complies with the “external wall” standards as per below

External Walls and Cladding

External walls for a BAL-40-rated property must be constructed using either:

  • Full masonry construction (brick, concrete blocks, stone)
  • Concrete panels or aerated concrete
  • Earth-covered walls meeting specific standards
  • All external joints must also be sealed against ember penetration to prevent gaps greater than 3mm
  • Vents and the like need screening with a mesh made of corrosion-resistant steel, bronze, or aluminium in any areas where the aperture is less than 3mm

BAL-40 Windows

BAL-40 window requirements include very specific protection measures to keep flames at bay:

  • Frames and window hardware must be metal only (e.g., aluminium or steel)
  • Minimum 6mm toughened glass to be used for all window assemblies
  • Bushfire shutters are also required in some circumstances where you have non-compliant windows
  • Windows that can open must have externally fitted screens to stop embers from entering
bal 40 meaning

BAL-40 Doors

For BAL-40 properties, doors must provide substantial protection:

  • Side-hung external doors must be completely non-combustible (metal construction) or a solid timber door (thickness of 35mm minimum) or protected by compliant bushfire shutters
  • If using glass panels, minimum 6mm toughened glass is required
  • Sliding doors must be totally protected by a bushfire shutter or, along with the toughened glass as mentioned above, the fixed and openable areas of the sliding door must be externally screened
  • All sliding door frames and externally fitted hardware that supports the door’s functioning should be metal
  • All types of doors should be tight fitting to their frames
  • Garage doors must be non-combustible and fitted with weather strips, seals, or guide tracks depending on the door type with no gaps anywhere around the doors that are greater than 3mm

BAL-40 Decking, Verandas, and Other Outdoor Zones

For attached structures in BAL-40 zones:

  • Non-combustible materials only for decking, stair treads, ramps, landings, etc.,
  • Balustrades, handrails, or other barriers that are less than 125mm from any glazing or combustible wall must be made of non-combustible material as well
  • Appropriate fire separation if connected to the main dwelling
  • Full enclosure of spaces beneath decks with non-combustible material

Need a BAL assessment for your BAL 40 property? Get a quote from SA’s accredited experts.

what is bal 40 timber

Navigating Complex Approvals

BAL-40 properties often face additional scrutiny during council approvals that we can help with:

  • Our comprehensive BAL assessments provide clear documentation
  • We offer pre-lodgement consultation to identify potential approval issues
  • Our technical reports reflect specific council requirements across different South Australian jurisdictions as needed

Recently, we worked with a client building a family home on a challenging sloped site in Mitcham with a BAL-40 rating. We recommended specific construction techniques and material choices that addressed these unique site conditions while maintaining the architect’s vision for a contemporary home with substantial glazing elements.

By collaborating early in the design process, we helped integrate BAL-40 requirements in ways that enhanced rather than compromised the building’s design.

Don’t Be Afraid to Ask for Help

Building in BAL-40 areas demands expert and up-to-date knowledge, careful planning, and meticulous attention to detail. With extensive experience across South Australia’s highest-risk bushfire regions, we bring this kind of expertise to every project. For specialised advice on your property or to book a comprehensive assessment, contact our team today.